REMOVAL CONTINUED
3. Loosen tube nut (Figure 2, Item 3) and remove line (Figure 2, Item 4) from condenser (Figure 2, Item 1).
4. Remove O-ring (Figure 2, Item 5) from line (Figure 2, Item 4). Discard O-ring.
5. Remove four bolts (Figure 2, Item 9) and washers (Figure 2, Item 10) from condenser (Figure 2, Item 1).
6. Remove two bolts (Figure 2, Item 8), washers (Figure 2, Item 7), and bracket (Figure 2, Item 2) from condenser
(Figure 2, Item 1).
7. Remove two grommets (Figure 2, Item 6) from bracket (Figure 2, Item 2).