Figure 19. Hose at Radiator.
RADIATOR DRAIN LINES REPLACEMENT

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1147    1148    1149    1150    1151  1152  1153    1154    1155    1156    1157  
img
.
TM 5-2410-241-23-1
0051
AFTERCOOLER PUMP INLET HOSES AND PIPE INSTALLATION CONTINUED
5. Install clamp (Figure 20, Item 5) and clamp (Figure 20, Item 1) on hose (Figure 20, Item 3).
6. Install hose (Figure 20, Item 3) on pipe (Figure 20, Item 4) and aftercooler pump (Figure 20, Item 2).
7. Tighten clamp (Figure 20, Item 5) and clamp (Figure 20, Item 1) on hose (Figure 20, Item 3).
8. Install engine enclosure left door guard (WP 0202).
Figure 20. Aftercooler Pump Hose.
0051
END OF TASK
FOLLOW-ON TASKS
00051
1. Fill cooling system (WP 0113).
2. Install front engine bottom guards (WP 0199).
3. Verify correct operation of machine (TM 5-2410-241-10).
END OF TASK
END OF WORK PACKAGE