REMOVAL CONTINUED
N OT E
Note harness routing, mark, and tag all electrical connectors to aid installation.
17. Disconnect connector (Figure 4, Item 6) from alternator (Figure 4, Item 5).
18. Remove bolt (Figure 4, Item 8), washers (Figure 4, Item 7) and harness clip (Figure 4, Item 9) from alternator
(Figure 4, Item 5).
19. Remove two nuts (Figure 4, Item 2), washers (Figure 4, Item 3) and harness clips (Figure 4, Item 4) from
temperature regulator (Figure 4, Item 10).
20. Position harness (Figure 4, Item 1) aside.
Figure 4. Alternator Harness.