TM 5-2410-241-23-2
0060
ETHER VALVE AND BOTTLE SUPPORT BRACKET REMOVAL
00060
1. Loosen clamp (Figure 6, Item 4) from bottle (Figure 6, Item 5).
2. Remove bottle (Figure 6, Item 5) from ether valve (Figure 6, Item 7) and clamp (Figure 6, Item 4).
3. Loosen tube nut (Figure 6, Item 9) and remove line (Figure 6, Item 10) from fitting (Figure 6, Item 8).
4. Remove two bolts (Figure 6, Item 12), washers (Figure 6, Item 13), and clamps (Figure 6, Item 11) from line
(Figure 6, Item 10). Position line aside.
5. Remove two bolts (Figure 6, Item 2), washers (Figure 6, Item 3), clip (Figure 6, Item 1), and clamp (Figure 6,
Item 4) from bracket (Figure 6, Item 6). Position clip and harness (Figure 6, Item 14) aside.
Figure 6. Ether Bottle and Line.
0060