TM 5-2410-241-23-2
0097
REMOVAL CONTINUED
C AU T I O N
Cap all A/C lines and fittings during removal to protect against contamination. Failure to
follow this caution may result in equipment damage.
N OT E
Tag lines to aid installation.
7. Loosen bolt (Figure 2, Item 4), plate (Figure 2, Item 3) and remove line (Figure 2, Item 2) and line (Figure 2,
Item 8) from A/C compressor (Figure 2, Item 1). Position lines aside.
N OT E
Tag and mark electrical connectors to aid installation.
8. Disconnect connector (Figure 2, Item 6) from connector (Figure 2, Item 7).
9. Position harness (Figure 2, Item 5) aside.