N OT E
Tag electrical connectors to aid installation.
4. Disconnect temperature sensor connector (Figure 2, Item 3) from wiring harness (Figure 2, Item 4).
5. Remove temperature sensor probe (Figure 2, Item 2) from pump (Figure 2, Item 1).
6. Remove and discard O-ring (Figure 2, Item 5) from temperature sensor probe (Figure 2, Item 2).
Figure 2. Temperature Sensor.
0141
7. Remove four bolts (Figure 3, Item 1) and plate (Figure 3, Item 2) from headliner (Figure 3, Item 3).
8. Remove mirror (Figure 3, Item 4) from bracket (Figure 3, Item 7).
9. Remove two bolts (Figure 3, Item 5), washers (Figure 3, Item 6), and bracket (Figure 3, Item 7) from headliner
(Figure 3, Item 3).