DISCONNECT SWITCH TO MACHINE GROUND CABLE REMOVAL CONTINUED
N OT E
Note cable routing to aid installation.
Tag and mark all electrical connections to aid installation.
6. Remove nut (Figure 6, Item 4), washer (Figure 6, Item 3), clamp (Figure 6, Item 1), and clamp (Figure 6,
Item 2) from machine.
7. Remove clamp (Figure 6, Item 2) from ground cable (Figure 6, Item 5).
8. Remove bolt (Figure 6, Item 7) and washer (Figure 6, Item 6) from machine.
9. Position cable (Figure 6, Item 8) aside.
10. Remove ground cable (Figure 6, Item 5) from machine.
Figure 6. Ground Cable.
0160
END OF TASK
CLEANING AND INSPECTION
000160
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).