ASSEMBLY CONTINUED
10. Install new gasket (Figure 26, Item 4) on safety valve housing (Figure 26, Item 1).
11. Install valve (Figure 26, Item 7), spring (Figure 26, Item 8), and bracket (Figure 26, Item 9) on safety valve
housing (Figure 26, Item 1).
12. Install safety valve housing (Figure 26, Item 1), two washers (Figure 26, Item 2), and new locknuts (Figure 26,
Item 3) on hydraulic tank (Figure 26, Item 10).
13. Install new O-ring (Figure 26, Item 6) on drain plug (Figure 26, Item 5).
14. Install drain plug (Figure 26, Item 5) on safety valve housing (Figure 26, Item 1).
Figure 26. Hydraulic Tank Safety Drain Valve.