Figure 1. Arctic Kit Heater Fuel Shutoff Valve.
Figure 3. Arctic Kit Heater Fuel Metering Pump.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  968    969    970    971    972  973  974    975    976    977    978  
img
.
TM 5-2410-241-23-3
0293
REMOVAL CONTINUED
N OT E
Note position and orientation of fittings.
13. Loosen tube nut (Figure 2, Item 6) and remove hose (Figure 2, Item 7) from T fitting (Figure 2, Item 4).
14. Remove O-ring (Figure 2, Item 5) from T fitting (Figure 2, Item 4). Discard O-ring.
15. Loosen tube nut (Figure 2, Item 1) and remove T fitting (Figure 2, Item 4) from elbow (Figure 2, Item 3).
16. Remove O-ring (Figure 2, Item 2) from elbow (Figure 2, Item 3). Discard O-ring.
Figure 2. Arctic Kit Heater Fuel Shutoff Valve.
0293