MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
0.
ENGINE CONTINUED
6. ENGINE STARTS BUT DIES.
Step 1.
Check for diagnostic codes.
a.
If diagnostic codes are present, notify Field Maintenance.
b.
If there are no diagnostic codes, go to Step 2.
Step 2.
Check for water in fuel (WP 0012).
a.
Drain fuel/water separator (WP 0012).
b.
If problem persists, proceed to Step 3.
Step 3.
Prime fuel system.
a.
With engine start switch in OFF position, turn electric fuel priming pump to ON position for
several seconds, then shut off (WP 0004).
b.
Attempt to start engine.
c.
If problem persists, notify Field Maintenance.
7. EXCESSIVE EXHAUST SMOKE AT NORMAL OPERATING TEMPERATURE.
Check air filters (WP 0013).
a.
Clean or replace air filters (WP 0013).
b.
If problem persists, notify Field Maintenance.
8. EXCESSIVE OIL CONSUMPTION.
Step 1.
Check for misreading of oil level.
a.
Accurately measure oil level (WP 0012).
b.
If problem persists, go to Step 2.
Step 2.
Check air filters (WP 0013).
a.
Clean or replace air filters (WP 0013).
b.
If problem persists, go to Step 3.
Step 3.
Check for loose or leaking oil lines and oil leaks.
a.
Tighten loose connections.
b.
If problem persists or leaks are found, notify Field Maintenance.
9. INTERMITTENT ENGINE SHUTDOWN.
Step 1.
Check for diagnostic codes.
a.
If diagnostic codes are present, notify Field Maintenance.
b.
If there are no diagnostic codes, go to Step 2.
Step 2.
Check air filters (WP 0013).
a.
Clean or replace air filters (WP 0013).
b.
If problem persists, notify Field Maintenance.