4
TM 5-2410-240-10
OPERATOR MAINTENANCE
-
ETHER STARTING AID CYLINDER REPLACEMENT
0015
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Equipment Condition
Materials/Parts
0
0
0
0
Ether starting aid cylinder
0
Estimated Time to Complete
0
0
0.2 Hr
0
WARN I N G
Ether fuel is extremely flammable and toxic. DO NOT smoke and make sure you are in a
well-ventilated area away from heat, open flames, or sparks. Wear eye protection. Avoid
contact with skin and eyes and avoid breathing ether fumes. If fluid enters or fumes irritate
the eyes, wash immediately with large quantities of clean water for 15 minutes. Seek
medical attention immediately if ether is inhaled or causes eye irritation. Failure to follow
this warning may cause serious injury or death to personnel.
REMOVAL
00015
1. Loosen clamp (Figure 1, Item 1).
2. Remove ether starting aid cylinder (Figure 1, Item 2) from valve (Figure 1, Item 3). Discard empty cylinder.
Figure 1. Ether Starting Aid Cylinder.
0015