CID FMI CODE
Test or Inspection
Corrective Action
0041-03 Sensor Power Sup-
7. Using digital multimeter (WP
Continuity - Proceed to step 8.
ply (8 DCV) Voltage Above
0283), test for continuity between
No Continuity - Replace chassis
Normal - Continued
pin 5 on chassis harness to
harness (WP 0153, WP 0154).
platform harness connector CH-
Ensure all harness connectors are
C1 (WP 0018, Figure 81) and pin
reconnected. Verify proper operation
1 on chassis harness left track
of machine (TM 5-2410-240-10).
speed sensor connector CH-C7
(WP 0018, Figure 86).
8. Using digital multimeter (WP
No Continuity - Proceed to step 9.
0283), test for continuity between
Continuity - Replace chassis harness
pin 5 on chassis harness to
(WP 0153, WP 0154). Ensure all
platform harness connector CH-
harness connectors are reconnected.
C1 (WP 0018, Figure 81) and all
Verify proper operation of machine
other pins on chassis harness to
(TM 5-2410-240-10).
platform harness connector
CH-C1 (WP 0018, Figure 81).
9. Disconnect platform harness
ECM J1 connector PL-C4 (WP
0018, Figure 217) from machine
ECM (WP 0147, WP 0149).
10. Using digital multimeter (WP
Continuity - Proceed to step 11.
0283), test for continuity between
No Continuity - Replace platform
pin 44 on platform harness ECM
wiring harness (WP 0150, WP 0155).
J1 connector PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) to pin 5 on platform
reconnected. Verify proper operation
harness to chassis harness con-
of machine (TM 5-2410-240-10).
nector PL-C18 (WP 0018, Figure
226).
11. Using digital multimeter (WP
No Continuity - Replace machine
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
pin 44 on platform harness ECM
harness connectors are reconnected.
J1 connector PL-C4 (WP 0018,
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J1 connec-
Continuity - Replace platform wiring
tor PL-C4 (WP 0018, Figure 217).
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).