Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  456    457    458    459    460  461  462    463    464    465    466  
img
. . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
0041-04 Sensor Power Sup-
16. Using digital multimeter (WP
No Continuity - Replace machine
ply (8 DCV) Voltage Below
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
Normal - Continued
pin 44 on platform harness ECM
harness connectors are reconnected.
J1 connector PL-C4 (WP 0018,
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J1 connec-
Continuity - Replace platform wiring
tor PL-C4 (WP 0018, Figure 217).
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
0091-02 Throttle Position
Switch Data Erratic, Intermit-
Always inspect harness connectors that are involved in circuit. Poor
tent or Incorrect
connections can often be the cause of an electrical circuit problem.
Verify that all connections in the circuit are clean, secure, and
connections are in good condition. If a problem with connection is
found, correct problem and verify diagnostic code is active before
performing this procedure.
Tag wiring harnesses to aid installation.
1. Connect MSD (WP 0016). Select
0091-02 Code Active - Proceed to
machine control ECM and check
step 2.
for diagnostic codes (WP 0013).
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Perform Throttle Switch Circuit
Return machine to service.
Test (WP 0035).
N OT E
0096-03 Fuel Level Sensor
Voltage Above Normal
Always inspect harness connectors that are involved in circuit. Poor
connections can often be the cause of an electrical circuit problem.
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with a connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
0096-03 Code Active - Proceed to
1. Connect MSD (WP 0016). Select
step 2.
machine control ECM and check
for diagnostic codes (WP 0013).
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
0020-13