Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  459    460    461    462    463  464  465    466    467    468    469  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
0096-04 Fuel Level Sensor
5. Disconnect fuel tank harness to
Voltage Below Normal - Con-
platform harness connector
tinued
FL-C1 (WP 0018, Figure 152)
from platform harness to fuel tank
harness connector PL-C11
(WP 0018, Figure 221).
6. Using digital multimeter
Continuity - Proceed to step 7.
(WP 0283), test for continuity
No Continuity - Replace chassis
between pin 4 on fuel tank
wiring harness (WP 0153, WP 0154).
harness to platform harness
Ensure all harness connectors are
connector FL-C1 (WP 0018,
reconnected. Verify proper operation
Figure 152) and pin 1 on fuel tank
of machine (TM 5-2410-240-10).
harness fuel level sensor
connector FL-C3 (WP 0018,
Figure 154).
7. Using digital multimeter
Continuity - Proceed to step 8.
(WP 0283), test for continuity
No Continuity - Replace chassis
between pin 5 on fuel tank
wiring harness (WP 0153, WP 0154).
harness to platform harness
Ensure all harness connectors are
connector FL-C1 (WP 0018,
reconnected. Verify proper operation
Figure 152) and pin 2 on fuel tank
of machine (TM 5-2410-240-10).
harness fuel level sensor
connector FL-C3 (WP 0018,
Figure 154).
8. Using digital multimeter
Continuity - Proceed to step 9.
(WP 0283), test for continuity
No Continuity - Replace chassis
between pin 4 on fuel tank
wiring harness (WP 0153, WP 0154).
harness to platform harness
Ensure all harness connectors are
connector FL-C1 (WP 0018,
reconnected. Verify proper operation
Figure 152) and all other pins on
of machine (TM 5-2410-240-10).
fuel tank harness to platform
harness connector
FL-C1 (WP 0018, Figure 152).
9. Disconnect platform harness
ECM J1 connector PL-C4 (WP
0018, Figure 217) from machine
ECM (WP 0147, WP 0149).
10. Using digital multimeter (WP
Continuity - Proceed to step 11.
0283), test for continuity between
No Continuity - Replace platform
pin 30 on platform harness ECM
wiring harness (WP 0150, WP 0155).
J1 connector PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) and pin 4 on platform
reconnected. Verify proper operation
harness to fuel tank harness
of machine (TM 5-2410-240-10).
connector PL-C11 (WP 0018,
Figure 221).
0020-16