Table 1. Blade, Winch, and Ripper Troubleshooting Without Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  972    973    974    975    976  977  978    979    980    981    982  
img
. . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
0358-03 Implement Pilot
Pressure Supply Voltage
Always inspect harness connectors thatare involved in the circuit. Poor
Above Normal
connections can often be the cause of an electrical circuit problem.
Verify that all connections in circuit are clean and secure, and
connections are in good condition. If a problem with connection is
found, correct problem and verify diagnostic code is active before
performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Chas-
sis Wiring Harness.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 0358-03 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Remove right rear access cover
from machine (WP 0191).
4. Disconnect platform wiring har-
ness connector PL-C18 (WP
0018, Figure 226) from chassis
wiring harness connector CH-C1
(WP 0018, Figure 81): with Ripper
(WP 0150); with Winch (WP
0155).
5. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
Code 0358-03 Remains Active - Pro-
6. Check for active code 0358-03 in
ceed to Test Step 2.
machine control D6K ECM (WP
0016).
Code 0358-03 Becomes Inactive -
Replace chassis wiring harness: with
Ripper (WP 0153); with Winch (WP
0154).
Proceed to step 7.
7. Using MSD (WP 0016), select
Code 0358-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 0358-03 is not active.
Code 0358-03 Not Active - Trouble-
shooting complete.