TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0358-05 Implement Pilot
7. Check for active code 0358-05 or
Code 0358-05 Remains Active - Pro-
Pressure Supply Current
0358-06 in machine control D6K
ceed to Test Step 2.
Below Normal - Continued
Code 0358-05 Becomes Inactive
and 0358-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from CH-C17
terminal 1 and terminal 2: with Ripper
Replace implement pilot pressure
0196) or with Winch (WP 0197).
Proceed to step 8.
Code 0358-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 0358-05 is not active.
Code 0358-05 Not Active - Trouble-
shooting complete.
Test Step 2. Test for Open Chassis
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-2410-240-10).
2. Remove jumper wire from CH-
C17 terminal 1 and terminal 2:
Figure 261).
3. Remove right rear access cover
from machine (WP 0191).
4. Disconnect platform wiring har-
ness connector PL-C18 (WP
0018, Figure 226) from chassis
wiring harness connector CH-C1
(WP 0150), with Winch (WP
0155).
5. Connect jumper wire between PL-
C18 terminal 18 and terminal 20
6. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
0023-19