TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0358-03 Implement Pilot
Test Step 2. Test E918-GN Imple-
Pressure Supply Voltage
Above Normal - Continued
Short to Other Circuits in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Disconnect platform wiring har-
Figure 218) from ECM J2: with
Ripper (WP 0147); with Winch
(WP 0149).
3. Disconnect platform wiring har-
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).
4. Disconnect platform wiring har-
Figure 215) from equipment ECM
(WP 0148).
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 6.
PL-C5 terminal 2 and all other cir-
Points - Replace platform wiring har-
218).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 7.
ure 218) and all circuits in PL-C4
Points - Replace platform wiring har-
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to Test Step 3.
ure 218) and all circuits in PL-C2
Points - Replace platform wiring har-
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
0023-16