0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0358-03 Implement Pilot
Test Step 2. Test E918-GN Imple-
Pressure Supply Voltage
ment Shutoff Solenoid Circuit for
Above Normal - Continued
Short to Other Circuits in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2: with
Ripper (WP 0147); with Winch
(WP 0149).
3. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).
4. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
5. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 6.
PL-C5 terminal 2 and all other cir-
Continuity on One or More Test
cuits in PL-C5 (WP 0018, Figure
Points - Replace platform wiring har-
218).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
6. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 7.
PL-C5 terminal 2 (WP 0018, Fig-
Continuity on One or More Test
ure 218) and all circuits in PL-C4
Points - Replace platform wiring har-
(WP 0018, Figure 217).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
7. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to Test Step 3.
PL-C5 terminal 2 (WP 0018, Fig-
Continuity on One or More Test
ure 218) and all circuits in PL-C2
Points - Replace platform wiring har-
(WP 0018, Figure 215).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.