0498-05 Blade Tilt Left Sole-
Test Step 4. Test H802-GY PMW
noid Current Below Normal -
Driver Return Circuit for High
Continued
Resistance or Open in Platform
Wiring Harness.
0283), measure resistance
Replace machine ECM: with Ripper
between PL-C4 terminal 60 (WP
(WP 0147); with Winch (WP 0149).
0018, Figure 217) and PL-C18
Connect platform wiring harness con-
226).
on chassis wiring harness connector
Ripper (WP 0150); with Winch (WP
0155).
Connect chassis wiring harness con-
nector CH-C21 on blade tilt left sole-
265).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 2.
Replace platform wiring harness: with
Ripper (WP 0150); with Winch (WP
0155).
Connect chassis wiring harness con-
nector CH-C21 on blade tilt left sole-
265).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 2.
Code 0498-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 0498-05 is not active.
Code 0498-05 Not Active - Trouble-
shooting complete.