TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0498-06 Blade Tilt Left Sole-
noid Current Above Normal -
platform wiring harness: with Ripper
Continued
(WP 0150); with Winch (WP 0155).
Connect chassis wiring harness con-
nector CH-C21 on blade tilt left sole-
265).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 9.
Code 0498-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 0498-06 is not active.
Code 0498-06 Not Active - Trouble-
shooting complete.
0498-13 Blade Tilt Left Sole-
Test Step 1. Check for Active Cali-
bration Code.
machine control D6K ECM and
verify 0498-13 is active.
3. Check for active code 0498-13 in
Code 0498-13 Remains Active - Pro-
machine control D6K ECM (WP
ceed to Test Step 2.
Code 0498-13 Becomes Inactive -
Troubleshooting complete.
Test Step 2. Verify Machine Control
D6K ECM is Programmed Correctly.
1. Verify machine control D6K ECM
Software Correct - Replace Machine
is flashed with correct software
ECM: with Ripper (WP 0147); with
Winch (WP 0149).
Proceed to step 2.
Software Incorrect - Flash machine
ECM with correct software (WP
2. Check for active code 0498-13 in
Code 0498-13 Active - Repeat trou-
machine control D6K ECM (WP
bleshooting code from the beginning.
Code 0498-13 Not Active - Trouble-
shooting complete.