Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1010    1011    1012    1013    1014  1015  1016    1017    1018    1019    1020  
img
. . . . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0498-06 Blade Tilt Left Sole-
Continuity on Test Point - Replace
noid Current Above Normal -
platform wiring harness: with Ripper
Continued
(WP 0150); with Winch (WP 0155).
Connect chassis wiring harness con-
nector CH-C21 on blade tilt left sole-
noid: with Ripper (WP 0018, Figure
94); with Winch (WP 0018, Figure
265).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 9.
9. Using MSD (WP 0016), select
Code 0498-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 0498-06 is not active.
Code 0498-06 Not Active - Trouble-
shooting complete.
0498-13 Blade Tilt Left Sole-
Test Step 1. Check for Active Cali-
noid Out of Calibration
bration Code.
1. Connect MSD (WP 0016). Select
machine control D6K ECM and
verify 0498-13 is active.
2. Perform calibration of blade tilt left
solenoid (WP 0033).
3. Check for active code 0498-13 in
Code 0498-13 Remains Active - Pro-
machine control D6K ECM (WP
ceed to Test Step 2.
0016).
Code 0498-13 Becomes Inactive -
Troubleshooting complete.
Test Step 2. Verify Machine Control
D6K ECM is Programmed Correctly.
1. Verify machine control D6K ECM
Software Correct - Replace Machine
is flashed with correct software
ECM: with Ripper (WP 0147); with
(WP 0017).
Winch (WP 0149).
Proceed to step 2.
Software Incorrect - Flash machine
ECM with correct software (WP
0017). Proceed to step 2.
2. Check for active code 0498-13 in
Code 0498-13 Active - Repeat trou-
machine control D6K ECM (WP
bleshooting code from the beginning.
0016).
Code 0498-13 Not Active - Trouble-
shooting complete.