TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
0498-06 Blade Tilt Left Sole-
noid Current Above Normal
Always inspect harness connectors thatare involved in the circuit. Poor
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If problem with connection is found, correct the
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Blade
Tilt Left Solenoid.
machine control D6K ECM and
verify 0498-06 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. For D6K Dozer with Ripper,
remove rear plates (WP 0191)
from machine to access valve
bank. For D6K Dozer with Winch,
remove rear bottom guards (WP
0156) from machine to access
valve bank.
4. Disconnect chassis wiring har-
ness connector CH-C21 from
5. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
6. Check for active code 0498-05 or
Code 0498-06 Remains Active - Pro-
0498-06 in machine control D6K
ceed to Test Step 2.
Code 0498-06 Becomes Inactive
and 0498-05 Becomes Active -
Ripper (WP 0196); with Winch (WP
0197).
Proceed to step 7.