• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1013    1014    1015    1016    1017  1018  1019    1020    1021    1022    1023  
img
. . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1197-03 Blade Lower Sole-
8. Using MSD (WP 0016), select
Code 1197-03 Active - Repeat trou-
noid Voltage Above Normal -
machine control D6K ECM and
bleshooting code from the beginning.
Continued
verify 1197-03 is not active.
Code 1197-03 Not Active - Trouble-
shooting complete.
Test Step 3. Test H714-OR Blade
Lower Solenoid Circuit for Short to
Other Voltage Source in Platform
Wiring Harness.
1. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
2. Using digital multimeter (WP
Voltage Greater Than 0.3 Volts -
0283), measure for voltage
Replace platform wiring harness: with
between PL-C4 terminal 68 (WP
Ripper (WP 0150); with Winch (WP
0018, Figure 217) and ground.
0155).
Proceed to step 3.
Voltage 0.3 Volts or Lower - Replace
machine ECM: with Ripper (WP
0147); with Winch (WP 0149).
Connect platform wiring harness con-
nector PL-C2 (WP 0018, Figure 215)
on equipment ECM (WP 0148).
Connect platform wiring harness con-
nector PL-C18 (WP 0018, Figure 226)
on chassis wiring harness connector
CH-C1 (WP 0018, Figure 81): with
Ripper (WP 0150); with Winch (WP
0155).
Proceed to step 3.
3. Using MSD (WP 0016), select
Code 1197-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1197-03 is not active.
Code 1197-03 Not Active - Trouble-
shooting complete.
0023-56


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.