TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1197-05 Blade Lower Sole-
noid Current Below Normal -
Replace platform wiring harness: with
Continued
Ripper (WP 0150); with Winch (WP
0155).
Connect chassis wiring harness con-
nector CH-C19 on blade lower sole-
263).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 2.
Code 1197-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1197-05 is not active.
Code 1197-05 Not Active - Trouble-
shooting complete.
N OT E
1197-06 Blade Lower Sole-
noid Current Above Normal
Always inspect harness connectors thatare involved in the circuit. Poor
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If problem with connection is found, correct the
problem and verify diagnostic code is active before performing this pro-
cedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Shorted Blade
machine control D6K ECM and
verify 1197-06 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. For D6K Dozer with Ripper,
remove rear plates (WP 0196)
from machine to access valve
bank. For D6K Dozer with Winch,
remove rear bottom guards (WP
0156) from machine to access
valve bank.