  1012    1013    1014    1015    1016  1017  1018    1019    1020    1021    1022  
img
. . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1197-03 Blade Lower Sole-
Test Step 2. Test H714-OR Blade
noid Voltage Above Normal -
Lower Solenoid Circuit for Short to
Continued
Other Circuits in Platform Wiring
Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).
3. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2: with
Ripper (WP 0147); with Winch
(WP 0149).
4. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
5. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 6.
PL-C4 terminal 68 and all other
Continuity on One or More Test
circuits in PL-C4 (WP 0018, Fig-
Points - Replace platform wiring har-
ure 217).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
6. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 7.
PL-C4 terminal 68 (WP 0018, Fig-
Continuity on One or More Test
ure 217) and all circuits in PL-C5
Points - Replace platform wiring har-
(WP 0018, Figure 218).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
7. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to Test Step 3.
PL-C4 terminal 68 (WP 0018, Fig-
Continuity on One or More Test
ure 217) and all circuits in PL-C2
Points - Replace platform wiring har-
(WP 0018, Figure 215).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.