Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1031    1032    1033    1034    1035  1036  1037    1038    1039    1040    1041  
img
. . . . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1198-05 Blade Raise Sole-
Test Step 4. Test 975-WH PMW
noid Current Below Normal -
Driver Return Circuit for High
Continued
Resistance or Open in Platform
Wiring Harness.
1. Using digital multimeter (WP
Resistance Less Than 5.0 Ohms -
0283), measure resistance
Replace machine ECM: with Ripper
between PL-C4 terminal 55 (WP
(WP 0147); with Winch (WP 0149).
0018, Figure 217) and PL-C18
Connect platform wiring harness con-
terminal 21 (WP 0018, Figure
nector PL-C18 (WP 0018, Figure 226)
226).
on chassis wiring harness connector
CH-C1 (WP 0018, Figure 81): with
Ripper (WP 0150); with Winch (WP
0155).
Connect chassis wiring harness con-
nector CH-C18 on blade raise sole-
noid: with Ripper (WP 0018, Figure
91); with Winch (WP 0018, Figure
262).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 2.
Resistance 5.0 Ohms or Greater -
Replace platform wiring harness: with
Ripper (WP 0150); with Winch (WP
0155).
Connect chassis wiring harness con-
nector CH-C18 on blade raise sole-
noid: with Ripper (WP 0018, Figure
91); with Winch (WP 0018, Figure
262).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 2.
2. Using MSD (WP 0016), select
Code 1198-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1198-05 is not active.
Code 1198-05 Not Active - Trouble-
shooting complete.
0023-74