TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1198-05 Blade Raise Sole-
7. Check for active code 1198-05 or
Code 1198-05 Remains Active - Pro-
noid Current Below Normal -
1198-06 in machine control D6K
ceed to Test Step 3.
Continued
Code 1198-05 Becomes Inactive
and 1198-06 Becomes Active - Turn
ignition switch and battery disconnect
switch to OFF position (TM 5-2410-
240-10).
Remove jumper wire from PL-C18 ter-
Figure 226).
Replace chassis wiring harness: with
Ripper (WP 0153); with Winch (WP
0154).
Proceed to step 8.
Code 1198-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1198-05 is not active.
Code 1198-05 Not Active - Trouble-
shooting complete.
Test Step 3. Test H713-PK Blade
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Remove jumper wire from PL-C18
terminal 19 and terminal 21 (WP
3. Disconnect platform wiring har-
Figure 217) from ECM J1: with
Ripper (WP 0147); with Winch
(WP 0149).
0023-72