• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1025    1026    1027    1028    1029  1030  1031    1032    1033    1034    1035  
img
. . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1198-03 Blade Raise Sole-
5. Using digital multimeter (WP
No Continuity on Any Test Points -
noid Voltage Above Normal -
0283), test for continuity between
Proceed to step 6.
Continued
PL-C4 terminal 67 and all other
Continuity on One or More Test
circuits in PL-C4 (WP 0018, Fig-
Points - Replace platform wiring har-
ure 217).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
6. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to step 7.
PL-C4 terminal 67 (WP 0018, Fig-
Continuity on One or More Test
ure 217) and all circuits in PL-C5
Points - Replace platform wiring har-
(WP 0018, Figure 218).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
7. Using digital multimeter (WP
No Continuity on Any Test Points -
0283), test for continuity between
Proceed to Test Step 3.
PL-C4 terminal 67 (WP 0018, Fig-
Continuity on One or More Test
ure 217) and all circuits in PL-C2
Points - Replace platform wiring har-
(WP 0018, Figure 215).
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
8. Using MSD (WP 0016), select
Code 1198-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1198-03 is not active.
Code 1198-03 Not Active - Trouble-
shooting complete.
0023-68