Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1030    1031    1032    1033    1034  1035  1036    1037    1038    1039    1040  
img
. . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1198-05 Blade Raise Sole-
4. Using digital multimeter (WP
Resistance Less Than 5.0 Ohms -
noid Current Below Normal -
0283), measure resistance
Proceed to Test Step 4.
Continued
between PL-C4 terminal 67 (WP
Resistance 5.0 Ohms or Greater -
0018, Figure 217) and PL-C18
Replace platform wiring harness: with
terminal 19 (WP 0018, Figure
Ripper (WP 0150); with Winch (WP
226).
0155).
Connect chassis wiring harness con-
nector CH-C18 on blade raise sole-
noid: with Ripper (WP 0018, Figure
91); with Winch (WP 0018, Figure
262).
For D6K Dozer with Ripper, install
rear plates on machine (WP 0196).
For D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 5.
5. Using MSD (WP 0016), select
Code 1198-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1198-05 is not active.
Code 1198-05 Not Active - Trouble-
shooting complete.
0023-73