TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
1198-05 Blade Raise Sole-
noid Current Below Normal
Always inspect harness connectors thatare involved in the circuit. Poor
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean and secure, and connections
are in good condition. If problem with connection is found, correct prob-
lem and verify diagnostic code is active before performing this proce-
dure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
Test Step 1. Test for Open Blade
machine control D6K ECM and
verify 1198-05 is active.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. For D6K Dozer with Ripper,
remove rear plates from machine
to access valve bank (WP 0196).
For D6K Dozer with Winch,
remove rear bottom guards (WP
0156) from machine to access
valve bank (WP 0197).
4. Disconnect chassis wiring har-
ness connector CH-C18 from
5. Connect jumper wire between
CH-C18 terminal 1 and terminal 2:
262).
6. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).