TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1933-03 Blade Angle Left
No Continuity on Any Test Points -
Proceed to Test Step 3.
mal - Continued
ure 215) and all circuits in PL-C4
Points - Replace platform wiring har-
ness: with Ripper (WP 0150); with
Winch (WP 0155).
Proceed to step 8.
Code 1933-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1933-03 is not active.
Code 1933-03 Not Active - Trouble-
shooting complete.
Test Step 3. Test 751-GN Blade
Short to Other Voltage Source in
Platform Wiring Harness.
1. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
Voltage Greater Than 0.3 Volts -
0283), measure for voltage
Replace platform wiring harness: with
between PL-C2 terminal 50 (WP
Ripper (WP 0150); with Winch (WP
0018, Figure 215) and ground.
0155).
Proceed to step 3.
Voltage 0.3 Volts or Less - Replace
equipment ECM (WP 0148).
Connect platform wiring harness con-
on ECM J2: with Ripper (WP 0147);
with Winch (WP 0149).
Connect platform wiring harness con-
on ECM J1: with Ripper (WP 0147);
with Winch (WP 0149).
Connect platform wiring harness con-
on chassis wiring harness connector
Ripper (WP 0150); with Winch (WP
0155).
Proceed to step 3.
Code 1933-03 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 1933-03 is not active.
Code 1933-03 Not Active - Trouble-
shooting complete.
0023-130