Figure 5. Configuration Menu.
Figure 7. Hystat Outputs.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1324    1325    1326    1327    1328  1329  1330    1331    1332    1333    1334  
img
.
TM 5-2410-240-23-1
0031
HYDROSTATIC PUMP AND MOTOR EFFICIENCY TEST CONTINUED
10. Release parking brake at the switch (TM 5-2410-240-10).
11. Select Hystat parameters, Highlight Parking Brake Lockout Configuration (Figure 6, Item 1) and verify that
Locked Out (Figure 6, Item 2) is displayed. Select Change button (Figure 6, Item 3) to change configuration.
12. Lift and support machine high enough so that tracks do not touch ground (WP 0281).
Figure 6. Parking Brake Lockout Configuration Change.