Figure 8. Configuration Menu.
FINAL HYDROSTATIC SPEED TEST

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1327    1328    1329    1330    1331  1332  1333    1334    1335    1336    1337  
img
.
TM 5-2410-240-23-1
0031
HYDROSTATIC PUMP AND MOTOR EFFICIENCY TEST CONTINUED
13. Select Hystat parameters, Highlight Parking Brake Lockout Configuration (Figure 9, Item 1) verify that Not
Locked Out (Figure 9, Item 2) is displayed. Select Change button (Figure 9, Item 3) to change configuration.
Figure 9. Parking Brake Lockout Configuration Change.
0031
14. Stop engine, relieve hydraulic system pressure (WP 0162), remove pressure gauges, and install cab floor plate
(WP 0205) when tests and adjustments are complete.
15. Remove support from machine and position on ground (WP 0281).
END OF TASK
0031-13