TM 5-2410-240-23-1
0031
FINAL HYDROSTATIC SPEED TEST CONTINUED
00031
12. Remove cab floor plate (WP 0205). Install pressure gauge at left side hydrostatic pump pressure tap (Figure
12, Item 2) and right side hydrostatic pump pressure tap (Figure 12, Item 1).
Figure 12. Hydrostatic Pump Reverse Pressure Test Ports.
0031
13. Lift and support machine high enough so that tracks do not touch ground (WP 0281).