TM 5-2410-240-23-1
0031
FINAL HYDROSTATIC SPEED TEST CONTINUED
00031
N OT E
Wait at least 30 seconds for diagnostic codes to become active.
6. Monitor active diagnostic codes with ET. Check and record any active diagnostic codes. If diagnostic codes are
7. Verify that machine is set to maximum forward ground speed and that reverse ground speed is 100 percent of
forward ground speed (TM 5-2410-240-10).
8. Select Hystat Inputs status screen (Figure 10, Item 1).
9. Monitor and record Drive Motor Speed/Direction (Figure 10, Item 4) minimum (Figure 10, Item 2), and
maximum (Figure 10, Item 3) values.
Figure 10. Drive Motor Speed/Direction Status Screen.
0031
10. Operate machine until hydraulic system oil temperature is at least 104F 9F (40 5C).