TM 5-2410-240-23-1
0031
INITIAL PRESSURE TEST CONTINUED
Table 1. Initial Pressure Test.
0031
Initial Pressure Test
Port Location
Test Port Designation
Pressure
Operating Condition
A
Right (rear) Hydrostatic
363 22 psi
Parking brake released,
Pump Charge Pressure Tap
(2500 150 kPa)
Drive position in neutral,
engine speed 2,100 RPM
B
Left (front) Hydrostatic Pump
22 11 psi (150 75 kPa)
Parking brake released,
Case Drain Pressure Tap
Drive position in neutral,
engine speed 2,100 RPM
C
Left (front) Hydrostatic Pump
450 22 psi
Parking brake released,
Charge Pressure Tap
(3100 150 kPa)
Drive position in neutral,
engine speed 2,100 RPM
D
Parking Brake Pressure Tap
450 22 psi
Machine tracks must be in
(3100 150 kPa)
motion. Lift and support
machine or operate while
recording pressures
E
Implement Pump (stand-by
696 44 psi
Parking brake released,
pressure) Discharge
(4800 300 kPa)
Drive position in neutral,
Pressure Tap
engine speed 2,100 RPM
Refer to Figure 31 for testing locations.
6. Engage the parking brake, and stop engine.
a. If the engine speed is not within specifications, refer to Engine Cannot Reach Top Engine Speed or Engine
b. If the charge pressure for Hydrostatic Pump is not within specifications, adjust the charge relief valve for
that circuit and perform the initial pressure test again. Refer to Charge Relief Valve Adjustment (WP 0030).
c.
If the implement pump standby pressure is not within specifications, perform Hydraulic Pump Test and
Adjustment (WP 0033).
d. If the brake pressure is not within specifications, perform Deceleration/Brake Pedal Test in this work
package.
END OF TASK