• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 4. Air Intake Temperature Sensor.
AIR INTAKE TEMPERATURE SENSOR REPLACEMENT - Continued

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  208    209    210    211    212  213  214    215    216    217    218  
img
.
TM 5-2410-240-23-2
0054
INSTALLATION CONTINUED
00054
4. Position bracket (Figure 5, Item 1) over air intake temperature sensor (Figure 5, Item 5) and tighten nut
(Figure 5, Item 2) on bracket.
5. Position harness (Figure 5, Item 4) and install new tiedown strap (Figure 5, Item 3) on bracket (Figure 5,
Item 1).
Figure 5. Harness Bracket.
0054
6. Install access door (Figure 6, Item 1), four washers (Figure 6, Item 2), and bolts (Figure 6, Item 3) on machine.
Figure 6. Access Door.
0054
END OF TASK
0054-5