Figure 3. Injection Pump Position Sensor.
FUEL INJECTOR REPLACEMENT SINGLE INJECTOR

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  339    340    341    342    343  344  345    346    347    348    349  
img
. .
TM 5-2410-240-23-2
0076
INSTALLATION CONTINUED
4. Turn fuel valve (Figure 4, Item 3) to the ON position.
5. Install panel (Figure 4, Item 2) and close door (Figure 4, Item 1) on machine.
Figure 4. Door.
0076
END OF TASK
FOLLOW-ON TASKS
00076
1. Install primary fuel filter (WP 0074).
2. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE
0076-5/(6 blank)