• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3. Wastegate Solenoid.
Figure 5. Connector.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  381    382    383    384    385  386  387    388    389    390    391  
img
.
TM 5-2410-240-23-2
0080
INSTALLATION
00080
1. Install bolt (Figure 3, Item 4), wastegate solenoid (Figure 3, Item 7), and bolt (Figure 3, Item 8) on machine.
N OT E
Route harness as noted during removal.
2. Route harness (Figure 3, Item 1) from wastegate solenoid (Figure 3, Item 7).
N OT E
A/C accumulator removed for clarity.
Remove caps and install lines as noted during removal.
3. Position lines (Figure 3, Items 2 and 5) on wastegate solenoid (Figure 3, Item 7).
4. Install fitting (Figure 3, Item 6) and fitting (Figure 3, Item 3) on wastegate solenoid (Figure 3, Item 7).
N OT E
Install lines as noted during removal.
5. Install harness (Figure 4, Item 3) on clip (Figure 4, Item 4).
6. Install harness (Figure 4, Item 2) on two clips (Figure 4, Item 1).
Figure 4. Harness.