AIR CLEANER SERVICE
Figure 2. Primary Air Filter Assembly.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  546    547    548    549    550  551  552    553    554    555    556  
img
.
TM 5-2410-240-23-2
0105
WARN I N G
If CBRN exposure is suspected, personnel wearing protective equipment should handle all
air cleaner media. Consult your CBRN Officer NCO for appropriate handling or disposal
procedures.
Refer to FM 3-11.3, Multiservice Tactics, Techniques, and Procedures for Chemical,
Biological, Radiological, and Nuclear Contamination Avoidance, FM 3-11.5, Multiservice
Tactics, Techniques, and Procedures for Chemical, Biological, Radiological, and Nuclear
Decontamination.
Allow engine to cool off before performing maintenance on air cleaner. Hot metal parts can
cause severe burns. Wear eye, hand, and skin protection when working with heated parts.
Failure to follow these warnings may cause injury or death to personnel.
REMOVAL
000105
1. Open left engine door (Figure 1, Item 1), remove tee bolt (Figure 1, Item 2) by hand, remove pre-cleaner
(Figure 1, Item 3), disengage four latches (Figure 1, Item 4) and remove cover (Figure 1, Item 5) from machine.