INSTALLATION CONTINUED
NOTE
Remove caps and install hoses as noted during removal.
2. Install pump (Figure 5, Item 9) and bolts (Figure 5, Item 8) on machine.
3. Tighten tee fitting (Figure 5, Item 7) 1/4 turn.
4. Install new O-ring (Figure 5, Item 4) on hose (Figure 5, Item 6).
5. Install hose (Figure 5, Item 6) and tighten tube nut (Figure 5, Item 5) on pump (Figure 5, Item 9).
6. Install elbow (Figure 5, Item 10), new O-ring (Figure 5, Item 4), fitting (Figure 5, Item 3), and new O-ring
(Figure 5, Item 11) on tee fitting (Figure 5, Item 7).
7. Install hose (Figure 5, Item 1) and tighten tube nut (Figure 5, Item 2) on pump (Figure 5, Item 9).
Figure 5. Pump.