HYDRAULIC FAN GEAR PUMP REPLACEMENT (WITH RIPPER)
Figure 3. Pump.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  683    684    685    686    687  688  689    690    691    692    693  
img
.
TM 5-2410-240-23-2
0122
REMOVAL
000122
1. Remove eight bolts (Figure 1, Item 3), washers (Figure 1, Item 2), and two covers (Figure 1, Item 1) from
machine.
Figure 1. Rear Cover.
0122
NOTE
Tag and cap all hoses and open ports to aid installation.
2. Loosen two hose clamps (Figure 2, Item 2) and remove hose (Figure 2, Item 1) from machine.
Figure 2. Supply Hose.
0122
0122-2