Figure 1. Rear Cover.
Figure 4. Pump O-ring.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  684    685    686    687    688  689  690    691    692    693    694  
img
.
TM 5-2410-240-23-2
0122
REMOVAL CONTINUED
NOTE
Tag and cap all hoses and open ports to aid installation.
3. Loosen tube nut (Figure 3, Item 2) and remove hose (Figure 3, Item 1) from pump (Figure 3, Item 9).
4. Remove O-ring (Figure 3, Item 11), fitting (Figure 3, Item 3), O-ring (Figure 3, Item 4) and elbow (Figure 3, Item
10) from tee fitting (Figure 3, Item 7).
5. Loosen tube nut (Figure 3, Item 5) and remove hose (Figure 3, Item 6) from pump (Figure 3, Item 9).
6. Remove O-ring (Figure 3, Item 4) from hose (Figure 3, Item 6). Discard O-ring.
7. Loosen tee fitting (Figure 3, Item 7) 1/4 turn.
8. Remove two bolts (Figure 3, Item 8) and pump (Figure 3, Item 9) from machine.
Figure 3. Pump.
0122