Figure 2. Hydraulic Fitting and O-Rings.
Figure 5. Tube and O-ring.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  715    716    717    718    719  720  721    722    723    724    725  
img
.
TM 5-2410-240-23-2
0125
REMOVAL CONTINUED
11. Remove four bolts (Figure 4, Item 1), washers (Figure 4, Item 2) and tube (Figure 4, Item 3) from pump
(Figure 4, Item 4).
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure that any lifting equipment used is in good condition
and of suitable load capacity. Keep clear of heavy parts supported by lifting equipment.
Failure to follow this warning may result in death or injury to personnel.
N OT E
Implement pump weighs approximately 60 lb (27 kg).
12. With assistance, remove four bolts (Figure 4, Item 6), washers (Figure 4, Item 5) and pump (Figure 4, Item 4)
from machine. Set pump on flat level surface.
Figure 4. Pump.
0125