Figure 7. Tube and O-ring.
Figure 10. Hydraulic Line, Fitting and O-rings.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  718    719    720    721    722  723  724    725    726    727    728  
img
.
TM 5-2410-240-23-2
0125
INSTALLATION CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure that any lifting equipment used is in good condition
and of suitable load capacity. Keep clear of heavy parts supported by lifting equipment.
Failure to follow this warning may result in death or injury to personnel.
N OT E
Implement pump weighs approximately 60 lb (27 kg).
3. With assistance, install pump (Figure 9, Item 4), four washers (Figure 9, Item 5), and bolts (Figure 9, Item 6) on
machine.
4. Install tube (Figure 9, Item 3), four washers (Figure 9, Item 2), and bolts (Figure 9, Item 1) on pump (Figure 9,
Item 4).
Figure 9. Pump.