Figure 14. Harness Connectors and Retaining Hardware Underneath Cab Floor.
Figure 16. Harness Connectors and Retaining Hardware Underneath Cab Floor.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  963    964    965    966    967  968  969    970    971    972    973  
img
.
TM 5-2410-240-23-2
0150
INSTALLATION
000150
N OT E
Assistance is required to pass harness and connectors between HVAC duct and machine.
1. Install harness (Figure 15, Item 5) on machine (Figure 15, Item 6).
N OT E
Install tiedown straps and electrical connectors as noted during removal.
2. Install 10 new tiedown straps (Figure 15, Item 4) on clips (Figure 15, Item 3) and harness (Figure 15, Item 5).
3. Connect three relays (Figure 15, Item 1) to harness (Figure 15, Item 5).
4. Install three relays (Figure 15, Item 1) on brackets (Figure 15, Item 2).
Figure 15. Harness Connectors and Retaining Hardware Underneath Cab Floor.