REMOVAL CONTINUED
N OT E
Note location of tiedown straps and tag and mark electrical connectors to aid installation.
13. Loosen two screws (Figure 7, Item 7) and disconnect harness connectors (Figure 7, Item 8) from machine
ECM (Figure 7, Item 6).
14. Remove tiedown straps (Figure 7, Item 3) from platform harness (Figure 7, Item 2) and bracket (Figure 7,
Item 1). Discard tiedown straps.
15. Remove tiedown straps (Figure 7, Item 4) from platform harness (Figure 7, Item 2) and clips
(Figure 7, Item 5). Discard tiedown straps.
Figure 7. Machine ECM Harness Connectors and Harness Retaining Hardware.