N OT E
Note location of tiedown straps and tag and mark electrical connectors to aid installation.
16. Remove tiedown strap (Figure 8, Item 4) from three platform harness connectors (Figure 8, Item 7) and clip
(Figure 8, Item 6). Discard tiedown strap.
17. Remove bolt (Figure 8, Item 2), washer (Figure 8, Item 3), clamp (Figure 8, Item 11), bracket (Figure 8,
Item 10), and spacer (Figure 8, Item 9) from bracket (Figure 8, Item 8).
18. Remove clamp (Figure 8, Item 11) from platform harness (Figure 8, Item 1).
19. Unlock and disconnect platform harness connector (Figure 8, Item 7) from connector cap (Figure 8, Item 5).