Figure 2. Ignition Switch Connection.
WASHER BOTTLE REPLACEMENT

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  416    417    418    419    420  421  422    423    424    425    426  
img
. .
TM 5-2410-240-23-3
0222
INSTALLATION
000222
N OT E
Install electrical connectors as tagged during removal.
1. Connect ignition switch electrical connector (Figure 2, Item 2) to wiring harness electrical connector (Figure 2,
Item 1).
2. Install ignition switch (Figure 3, Item 2) and two bolts (Figure 3, Item 3) on dash panel (Figure 3, Item 1).
Figure 3. Ignition Switch.
0222
END OF TASK
FOLLOW-ON TASKS
000222
1. Install instrument cluster (WP 0221).
2. Verify correct operation of ignition switch (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE
0222-3/(4 blank)