TM 5-2410-240-23-3
0265
INSTALLATION CONTINUED
12. Install upper debris guard (Figure 17, Item 3), two washers (Figure 17, Item 2), and bolts (Figure 17, Item 1) on
upper winch mounting bracket (Figure 17, Item 4). Torque bolts to 35 lb-ft (47 Nm).
Figure 17. Upper Debris Guard and Retaining Hardware.
0265
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may cause injury to personnel.
N OT E
Make sure paint, rust, dirt, and grease are removed from mounting surface of winch, upper
winch mounting bracket, and machine.