TM 5-2410-241-23-1
0019
Table 2. Engine Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
41-3 8 Volt DC Supply Short
1.
If voltage of 7.6 - 8.4 Volts is
to +Batt - Continued
(WP 0296), measure for voltage
found, replace decelerator pedal
between pins A and B on deceler-
sensor (WP 0258). Ensure all
ator position sensor connector
harness connectors are recon-
nected. Verify correct operation of
machine (TM 5-2410-241-10).
2. If 7.6 - 8.4 Volts is not found, pro-
ceed to step 6.
6. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
7. Disconnect platform harness
Figure 11) from engine harness
Figure 12).
(WP 0296), test for continuity
step 9.
between pin 19 on platform har-
ness connector MA-C22
platform harness (WP 0209) and
instrument panel harness
on decelerator position sensor
(WP 0260). Ensure all harness
connectors are reconnected. Ver-
Figure 9).
ify correct operation of machine
(TM 5-2410-241-10).
9. Disconnect engine ECM connec-
from engine ECM (WP 0101).
(WP 0296), test for continuity
engine ECM (WP 0101). Ensure
between pin 19 on engine har-
all harness connectors are recon-
nected. Verify correct operation of
Figure 12) and pin 4 engine ECM
machine (TM 5-2410-241-10).
Figure 1).
Ensure all harness connectors
are reconnected. Verify
correct operation of machine
(TM 5-2410-241-10).
41-4 8 Volt DC Short to
1. If active 41-4 code is present, pro-
Ground
3176C D7 engine ECM and check
ceed to step 2.
for Diagnostic Codes or Event
2. If no active codes are present,
problem does not exist at this
time. Resume normal operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
0019-29