• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Powertrain Troubleshooting Procedures - Continued.
Table 1. Powertrain Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  505    506    507    508    509  510  511    512    513    514    515  
img
. . . . . . .
TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
468-3 Service Brake Pedal
42. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
Position Sensor Voltage
0296), test for continuity between
to step 43.
Above Normal - Contin-
pin 3 on platform harness connec-
2. If continuity is found, replace plat-
ued
tor MA-C3 (WP 0018, Figure 21)
form harness (WP 0209) and
and all other pins in platform har-
instrument panel harness (WP
ness connector MA-C3 (WP 0018,
0260). Replace Fuse #5 (TM 5-
Figure 21).
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
43. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 44.
pin 3 on platform harness connec-
2. If continuity is found, replace plat-
tor MA-C3 (WP 0018, Figure 21)
form harness (WP 0209) and
and machine ground.
instrument panel harness (WP
0260). Replace Fuse #5 (TM 5-
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
44. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 45.
pin 6 on platform harness connec-
2. If continuity is found, replace plat-
tor MA-C14 (WP 0018, Figure 33)
form harness (WP 0209) and
and all other pins in platform har-
instrument panel harness (WP
ness connector MA-C14 (WP
0260). Replace Fuse #5 (TM 5-
0018, Figure 33).
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
45. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 46.
pin 6 on platform harness connec-
2. If continuity is found, replace plat-
tor MA-C14 (WP 0018, Figure 33)
form harness (WP 0209) and
and machine ground.
instrument panel harness (WP
0260). Replace Fuse #5 (TM 5-
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
0020-79


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.